protobuf/ingestor.proto Normal file
View File

@@ -0,0 +1,329 @@
syntax = "proto3";
option java_multiple_files = true;
option java_package = "com.dexorder.proto";
// Request for data ingestion (used in Relay → Ingestor work queue)
message DataRequest {
// Unique request ID for tracking
string request_id = 1;
// Type of request
RequestType type = 2;
// Market identifier
string ticker = 3;
// For historical requests
optional HistoricalParams historical = 4;
// For realtime requests
optional RealtimeParams realtime = 5;
// Optional client ID for notification routing (async architecture)
// Flink uses this to determine notification topic
optional string client_id = 6;
enum RequestType {
HISTORICAL_OHLC = 0;
REALTIME_TICKS = 1;
}
}
message HistoricalParams {
// Start time (microseconds since epoch)
uint64 start_time = 1;
// End time (microseconds since epoch)
uint64 end_time = 2;
// OHLC period in seconds (e.g., 60 = 1m, 300 = 5m, 3600 = 1h, 86400 = 1d)
uint32 period_seconds = 3;
// Maximum number of candles to return (optional limit)
optional uint32 limit = 4;
}
message RealtimeParams {
// Whether to include tick data
bool include_ticks = 1;
// Whether to include aggregated OHLC
bool include_ohlc = 2;
// OHLC periods to generate in seconds (e.g., [60, 300, 900] for 1m, 5m, 15m)
repeated uint32 ohlc_period_seconds = 3;
}
// Control messages for ingestors (Flink → Ingestor control channel)
message IngestorControl {
// Control action type
ControlAction action = 1;
// Request ID to cancel (for CANCEL action)
optional string request_id = 2;
// Configuration updates (for CONFIG_UPDATE action)
optional IngestorConfig config = 3;
enum ControlAction {
CANCEL = 0; // Cancel a specific request
SHUTDOWN = 1; // Graceful shutdown signal
CONFIG_UPDATE = 2; // Update ingestor configuration
HEARTBEAT = 3; // Keep-alive signal
}
}
message IngestorConfig {
// Maximum concurrent requests per ingestor
optional uint32 max_concurrent = 1;
// Request timeout in seconds
optional uint32 timeout_seconds = 2;
// Kafka topic for output
optional string kafka_topic = 3;
}
// Historical data response from ingestor to Flink (Ingestor → Flink response channel)
message DataResponse {
// Request ID this is responding to
string request_id = 1;
// Status of the request
ResponseStatus status = 2;
// Error message if status is not OK
optional string error_message = 3;
// Serialized OHLC data (repeated OHLCV protobuf messages)
repeated bytes ohlc_data = 4;
// Total number of candles returned
uint32 total_records = 5;
enum ResponseStatus {
OK = 0;
NOT_FOUND = 1;
ERROR = 2;
}
}
// Client request submission for historical OHLC data (Client → Relay)
// Relay immediately responds with SubmitResponse containing request_id
message SubmitHistoricalRequest {
// Client-generated request ID for tracking
string request_id = 1;
// Market identifier (e.g., "BINANCE:BTC/USDT")
string ticker = 2;
// Start time (microseconds since epoch)
uint64 start_time = 3;
// End time (microseconds since epoch)
uint64 end_time = 4;
// OHLC period in seconds (e.g., 60 = 1m, 300 = 5m, 3600 = 1h)
uint32 period_seconds = 5;
// Optional limit on number of candles
optional uint32 limit = 6;
// Optional client ID for notification routing (e.g., "client-abc-123")
// Notifications will be published to topic: "RESPONSE:{client_id}"
optional string client_id = 7;
}
// Immediate response to SubmitHistoricalRequest (Relay → Client)
message SubmitResponse {
// Request ID (echoed from request)
string request_id = 1;
// Status of submission
SubmitStatus status = 2;
// Error message if status is not QUEUED
optional string error_message = 3;
// Topic to subscribe to for result notification
// e.g., "RESPONSE:client-abc-123" or "HISTORY_READY:{request_id}"
string notification_topic = 4;
enum SubmitStatus {
QUEUED = 0; // Request queued successfully
DUPLICATE = 1; // Request ID already exists
INVALID = 2; // Invalid parameters
ERROR = 3; // Internal error
}
}
// Historical data ready notification (Flink → Relay → Client via pub/sub)
// Published after Flink writes data to Iceberg
message HistoryReadyNotification {
// Request ID
string request_id = 1;
// Market identifier
string ticker = 2;
// OHLC period in seconds
uint32 period_seconds = 3;
// Start time (microseconds since epoch)
uint64 start_time = 4;
// End time (microseconds since epoch)
uint64 end_time = 5;
// Status of the data fetch
NotificationStatus status = 6;
// Error message if status is not OK
optional string error_message = 7;
// Iceberg table information for client queries
string iceberg_namespace = 10;
string iceberg_table = 11;
// Number of records written
uint32 row_count = 12;
// Timestamp when data was written (microseconds since epoch)
uint64 completed_at = 13;
enum NotificationStatus {
OK = 0; // Data successfully written to Iceberg
NOT_FOUND = 1; // No data found for the requested period
ERROR = 2; // Error during fetch or processing
TIMEOUT = 3; // Request timed out
}
}
// Legacy message for backward compatibility (Client → Relay)
message OHLCRequest {
// Request ID for tracking
string request_id = 1;
// Market identifier
string ticker = 2;
// Start time (microseconds since epoch)
uint64 start_time = 3;
// End time (microseconds since epoch)
uint64 end_time = 4;
// OHLC period in seconds (e.g., 60 = 1m, 300 = 5m, 3600 = 1h)
uint32 period_seconds = 5;
// Optional limit on number of candles
optional uint32 limit = 6;
}
// Generic response for any request (Flink → Client)
message Response {
// Request ID this is responding to
string request_id = 1;
// Status of the request
ResponseStatus status = 2;
// Error message if status is not OK
optional string error_message = 3;
// Generic payload data (serialized protobuf messages)
repeated bytes data = 4;
// Total number of records
optional uint32 total_records = 5;
// Whether this is the final response (for paginated results)
bool is_final = 6;
enum ResponseStatus {
OK = 0;
NOT_FOUND = 1;
ERROR = 2;
}
}
// CEP trigger registration (Client → Flink)
message CEPTriggerRequest {
// Unique trigger ID
string trigger_id = 1;
// Flink SQL CEP pattern/condition
string sql_pattern = 2;
// Markets to monitor
repeated string tickers = 3;
// Callback endpoint (for DEALER/ROUTER routing)
optional string callback_id = 4;
// Optional parameters for the CEP query
map<string, string> parameters = 5;
}
// CEP trigger acknowledgment (Flink → Client)
message CEPTriggerAck {
// Trigger ID being acknowledged
string trigger_id = 1;
// Status of registration
TriggerStatus status = 2;
// Error message if status is not OK
optional string error_message = 3;
enum TriggerStatus {
REGISTERED = 0;
ALREADY_REGISTERED = 1;
INVALID_SQL = 2;
ERROR = 3;
}
}
// CEP trigger event callback (Flink → Client)
message CEPTriggerEvent {
// Trigger ID that fired
string trigger_id = 1;
// Timestamp when trigger fired (microseconds since epoch)
uint64 timestamp = 2;
// Schema information for the result rows
ResultSchema schema = 3;
// Result rows from the Flink SQL query
repeated ResultRow rows = 4;
// Additional context from the CEP pattern
map<string, string> context = 5;
}
message ResultSchema {
// Column names in order
repeated string column_names = 1;
// Column types (using Flink SQL type names)
repeated string column_types = 2;
}
message ResultRow {
// Encoded row data (one bytes field per column, in schema order)
// Each value is encoded as a protobuf-serialized FieldValue
repeated bytes values = 1;
}
message FieldValue {
oneof value {
string string_val = 1;
int64 int_val = 2;
double double_val = 3;
bool bool_val = 4;
bytes bytes_val = 5;
uint64 timestamp_val = 6;
}
}